A bump test is a quick check that exposes a gas detector to a known gas to confirm its sensors respond and its alarms work before the detector is used to protect workers.

A bump test, also called a function check, is a short test in which a portable gas detector is exposed to a known concentration of test gas that is high enough to set off its alarms. The test confirms that the sensors respond and that the audible, visual and vibrating alarms work.
Gas sensors can fail without warning. They can be poisoned by silicones or other chemicals, clogged by dust or water, damaged by drops, or simply wear out. A detector with a failed sensor may still turn on and show zero, giving a worker false confidence in a dangerous atmosphere. A bump test is the simplest way to catch that before entry into a confined space or other hazardous area.
A gas detector is often the only thing standing between a worker and an invisible, odorless hazard such as carbon monoxide, oxygen deficiency or a flammable atmosphere. If the detector cannot sense the gas, the worker has no warning at all. Bump testing takes a minute or two and turns an assumption into a verified fact.
Records of bump tests also show regulators, customers and investigators that the employer took reasonable steps to make sure monitoring equipment worked when it was used.
A contractor preparing to enter a lift station wet well picked up a four-gas detector from the truck. The display read normal in fresh air. When he bump tested it, the hydrogen sulfide sensor did not respond. A later check found the sensor had failed after the unit was dropped the week before.
He used a spare detector that passed its bump test and found 25 ppm H2S in the well, so the crew ventilated before entry. The company then bought docking stations, required daily bump tests with logged results and added drop events to its retest rules.
OSHA guidance and ISEA recommend a bump test or calibration check before each day's use, following the manufacturer's instructions. Many employers test before each shift or each entry.
A bump test checks that sensors and alarms respond to gas. Calibration adjusts the detector so its readings match a known gas concentration.
It should not be used. Calibrate it according to the manufacturer's instructions and retest. If it still fails, remove it from service for repair.
Yes. A manual bump test uses a cylinder of test gas, a regulator and tubing or a cap. The result should be recorded.
Usually under a minute or two per detector. Docking stations can test several units quickly and keep the records automatically.
Most four-gas detectors use a mixed test gas containing set amounts of methane or pentane for the LEL sensor, carbon monoxide, hydrogen sulfide and reduced oxygen. Always use the mix the manufacturer specifies.
Part of SafetyIQ's EHS glossary: plain-English definitions of workplace health and safety terms.