EHS glossary>Safety term

The Definition of Legionella (Legionnaires' Disease)

Legionella is a bacterium that grows in building water systems such as cooling towers and plumbing and causes Legionnaires' disease, a severe pneumonia, when people breathe in contaminated water droplets.

Plain-English definition
Real-world example
Legionella (Legionnaires' Disease) definition

Definition of Legionella (Legionnaires' Disease)

Legionella is a type of bacteria found naturally in fresh water. It becomes a health hazard when it grows in human-made water systems and spreads through mist or droplets that people breathe in. The infection it causes is legionellosis, which includes Legionnaires' disease, a serious type of pneumonia, and Pontiac fever, a milder flu-like illness.

The disease gets its name from a 1976 outbreak at an American Legion convention in Philadelphia. Legionnaires' disease is not usually spread from person to person. Older people, smokers and people with weakened immune systems or chronic lung disease are most at risk.

Why Legionella Matters

Legionnaires' disease is preventable, yet outbreaks still happen every year, often linked to a single cooling tower or poorly maintained hot water system. One contaminated source can sicken workers, visitors and people in the surrounding neighborhood, with serious legal and reputational consequences for the building owner.

For safety teams, Legionella is a reminder that hazards can come from building systems, not just production processes. Maintenance workers who clean cooling towers or work near contaminated spray face the highest risk, and facilities that shut down or run at low occupancy can see bacteria grow quickly in stagnant water.

How Legionella Spreads at Work

Conditions for Growth

  • Warm water: Legionella grows best between about 77 and 113 degrees Fahrenheit (25 to 45 degrees Celsius).
  • Stagnant water: Dead legs, unused outlets and low-flow pipes let bacteria multiply.
  • Biofilm and sediment: Scale, rust and slime feed and protect the bacteria.
  • Low disinfectant: Not enough chlorine or other disinfectant reaching the water.

Common Sources

  • Cooling towers and evaporative condensers on large building and industrial systems.
  • Hot water systems and showers in hotels, hospitals and workplaces.
  • Decorative fountains, hot tubs and humidifiers.
  • Industrial processes that create spray, such as pressure washing and some metalworking fluids.

Regulations and Standards

Standards and Guidance

  • ASHRAE Standard 188: Sets minimum requirements for a Legionella risk management program for building water systems.
  • CDC toolkit: The CDC's water management program toolkit explains how to identify risk areas, set control limits and respond when limits are not met.
  • Healthcare: The Centers for Medicare and Medicaid Services expects hospitals and nursing homes to have water management programs.
  • OSHA: OSHA has no specific Legionella standard but publishes technical guidance and can cite serious hazards under the General Duty Clause.
  • Local rules: Some cities and states require cooling tower registration, testing and inspections.

Good Practices for Legionella Control

  • Build a water management team: Assign people to own the program and keep records.
  • Map the system: Draw a diagram of water flow and mark where Legionella could grow or spread.
  • Set control limits: Monitor temperature, disinfectant levels and pH, and act when readings drift.
  • Flush and clean: Flush unused outlets, remove dead legs, and clean and disinfect cooling towers on a schedule.
  • Protect maintenance workers: Use respiratory protection when cleaning cooling towers or working near contaminated spray.
  • Restart carefully: Flush and test systems after shutdowns, renovations or low occupancy.

Common Mistakes With Legionella

  • Having a plan on paper only: A water management plan only works if readings are taken and acted on.
  • Forgetting rarely used outlets: Eyewash stations, safety showers and unused sinks can harbor bacteria if not flushed.
  • Skipping restart steps: Reopening after a shutdown without flushing and disinfecting is a common outbreak trigger.
  • Keeping hot water too cool: Lowering water heater temperatures to save energy can create ideal growth conditions.
  • Unprotected tower cleaning: Cleaning cooling towers without respiratory protection exposes workers to contaminated aerosol.

Example of Legionella Exposure

After a manufacturing plant restarted following a three-week shutdown, two maintenance workers developed pneumonia. Health officials traced the illnesses to the plant's cooling tower, which had sat warm and untreated during the outage.

The plant created a water management program based on ASHRAE 188, added automatic biocide dosing and monthly testing, wrote a restart procedure that required cleaning and disinfection after any shutdown, and required respirators for tower maintenance.

Frequently Asked Questions: Legionella (Legionnaires' Disease)

How do people catch Legionnaires' disease?

By breathing in small droplets of water that contain Legionella, such as mist from cooling towers, showers or hot tubs. It is not usually spread from person to person.

What temperature kills Legionella?

Legionella grows best in warm water and stops multiplying at higher temperatures. Many programs store hot water at 140 degrees Fahrenheit (60 degrees Celsius) or above, balanced against scald risk at the tap.

Does OSHA regulate Legionella?

There is no specific OSHA standard, but OSHA provides guidance and can use the General Duty Clause for serious hazards. ASHRAE 188 and CDC guidance are the main references for building owners.

What is a water management program?

It is a written plan to find where Legionella could grow in a building's water systems, control those conditions with monitoring and maintenance, and correct problems when they are found.

What are the symptoms of Legionnaires' disease?

Symptoms are similar to other pneumonias and include cough, fever, shortness of breath, muscle aches and headaches. They usually start 2 to 14 days after exposure. A urine or sputum test can confirm it.

Can emergency eyewash stations grow Legionella?

Yes, if water sits stagnant in the lines. Weekly activation of plumbed eyewash and shower units helps flush the lines and keeps water fresh.

Related Terms

Part of SafetyIQ's EHS glossary: plain-English definitions of workplace health and safety terms.

> Keep learning

More EHS terms

Browse the full glossary >

> See it in action

Put these safety terms into practice with SafetyIQ

Capture hazards, run inspections, track training and close out corrective actions in one platform built for high-risk, field-heavy work.

Book my free demo
★★★★★
4.8 out of 5 stars on
G2
G2 High Performer, Fall 2026