Step and touch potential are dangerous voltage differences that form in the ground and on equipment around an electrical fault, such as a downed line or a crane touching a power line, that can shock nearby people.

Plain-English definition
Real-world example
Step and Touch Potential definition

Definition of Step and Touch Potential

Step and touch potential describe the voltage differences that can shock a person standing near an electrical fault to ground. When current flows into the earth, from a downed power line, a fault at a substation or equipment that contacts an energized line, the voltage is highest at the point of contact and drops off with distance, forming rings of different voltage in the ground.

  • Step potential: The voltage difference between a person's two feet as they stand or walk across those rings. Current can flow up one leg and down the other.
  • Touch potential: The voltage difference between a person's hand touching an energized object, such as a truck, crane or fence, and their feet on the ground. Current can flow through the arm, chest and heart.

Both can be fatal, even when the person never touches the power line itself. Line workers, crane and boom truck operators, tree trimmers, firefighters and anyone working near overhead power lines or substations are at risk.

Why Step and Touch Potential Matter

Many power line deaths are not the operator in the cab but a ground worker who was touching the truck, holding a tag line or walking toward the machine to help. People often assume that if they are not touching the wire, they are safe. Step and touch potential explain why that is wrong and why the area around a contact can be deadly.

Understanding these hazards changes behavior at the moment it matters most. Crews who know to stay back, stay on the machine and shuffle away are far more likely to survive a line contact or a downed conductor than crews who rush in to help.

How Step and Touch Potential Form

Common Situations

  • Equipment contact: A crane boom, dump truck bed or aerial device touches an overhead line, energizing the whole machine.
  • Downed conductors: A line falls to the ground after a storm or vehicle crash.
  • Substation faults: A ground fault raises the voltage of the ground grid and nearby fences.
  • Work on de-energized lines: Accidental re-energization or induced voltage from nearby lines.

Factors That Affect the Hazard

  • Fault current and voltage: Higher values create stronger gradients.
  • Soil conditions: Wet or low-resistance soil changes how voltage spreads.
  • Distance: The voltage gradient is steepest close to the contact point.

Regulations and Standards

  • OSHA power generation and distribution rules: 29 CFR 1910.269 and 29 CFR 1926 Subpart V require employers to protect workers from hazardous differences in electrical potential, including through protective grounding and equipotential zones, and to protect workers from hazards when mechanical equipment could contact energized lines.
  • Cranes: 29 CFR 1926 Subpart CC, including 1926.1408, sets clearances and precautions for equipment working near power lines.
  • Substation design: IEEE Std 80 is the main guide for designing substation grounding to keep step and touch voltages within safe limits.
  • Electrical safe work practices: NFPA 70E and 29 CFR 1910.333 cover work near energized parts.

Good Practices for Step and Touch Potential

  • Keep clearances: Maintain minimum approach distances and use a dedicated spotter for equipment near lines.
  • Create equipotential zones: Use protective grounds, grounding and bonding and ground mats so workers and equipment are at the same potential.
  • Barricade energized equipment: Keep people from touching trucks and equipment that could become energized.
  • Stay on the equipment: If equipment contacts a line, the operator should stay put unless there is a fire, and warn others to keep away.
  • Jump and shuffle: If escape is necessary, jump clear with feet together without touching the machine and ground at the same time, then shuffle or hop away with feet close together.
  • Treat downed lines as live: Stay well back and call the utility.

Common Step and Touch Potential Mistakes

  • Rushing to help: Coworkers who run toward an energized truck or a shocked person can become victims too.
  • Climbing down normally: Stepping off with one foot on the machine and one on the ground creates a path for current.
  • Assuming a line is dead: Downed or sagging lines may still be energized or may re-energize automatically.
  • Holding conductive tag lines: Wet or conductive lines can carry current to the worker holding them.
  • Grounding only the equipment: Grounding a truck without bonding and mats can still leave workers exposed to touch potential.

Example of Step and Touch Potential

A boom truck operator delivering trusses swung the boom into a 7,200-volt distribution line. A laborer standing beside the truck reached out to steady the tag line and was shocked through his hand and feet. The operator stayed in the cab, shouted for everyone to stay back and called 911, and the utility de-energized the line.

The laborer survived with burns. The company added power line surveys to its lift plans, required a dedicated spotter and nonconductive tag lines near lines, and trained all crew members on step and touch potential and what to do after a contact.

Frequently Asked Questions: Step and Touch Potential

What is the difference between step potential and touch potential?

Step potential is the voltage between a person's feet as they stand on energized ground. Touch potential is the voltage between a hand on an energized object and the feet on the ground.

Why should you shuffle away from a downed power line?

Keeping your feet close together and on the ground reduces the voltage difference between them, lowering the chance that current flows through your legs.

What should an operator do if equipment touches a power line?

Stay on the equipment unless there is a fire or other immediate danger, warn others to stay away and call for the line to be de-energized. If you must leave, jump clear without touching the machine and ground together, then shuffle away.

What is an equipotential zone?

It is a work area where grounding and bonding keep the worker and nearby conductive objects at the same voltage, so that no dangerous current flows through the body.

How far away from a downed power line should you stay?

Many utilities advise staying at least 35 feet away, and farther for high-voltage lines or wet ground. Keep everyone back and wait for the utility to confirm the line is de-energized.

Can step potential occur without a downed line?

Yes. Ground faults at substations, lightning strikes and equipment contacting energized lines can all create voltage gradients in the ground.

Related Terms

Part of SafetyIQ's EHS glossary: plain-English definitions of workplace health and safety terms.

> Keep learning

More EHS terms

Browse the full glossary >

> See it in action

Put these safety terms into practice with SafetyIQ

Capture hazards, run inspections, track training and close out corrective actions in one platform built for high-risk, field-heavy work.

Book my free demo
★★★★★
4.8 out of 5 stars on
G2
G2 High Performer, Fall 2026