Home › Chemical library › Carbon Monoxide
Gas · Toxic and flammable

Carbon Monoxide

Also known asCarbon oxide, Flue gas, Carbonic oxide
CAS630-08-0EC211-128-3UN1016DOT class2.3 (subsidiary 2.1)FormulaCO
Danger
At a glance
Flash pointFlammable gas
OSHA PEL50 ppm (55 mg/m³) TWA
NIOSH REL35 ppm TWA; 200 ppm Ceiling
ACGIH TLV25 ppm TWA
IDLH1200 ppm
Explosive range12.5–74% in air
Sources: NIOSH Pocket Guide, OSHA, ACGIH. Check your supplier's SDS.

GHS hazards

Danger

Classification

Flammable gas, Category 1; Gas under pressure; Acute toxicity (inhalation), Category 3; Reproductive toxicity, Category 1A; Specific target organ toxicity, repeated exposure, Category 1

Hazard statements

  • H220 Extremely flammable gas.
  • H280 Contains gas under pressure; may explode if heated.
  • H331 Toxic if inhaled.
  • H360D May damage the unborn child.
  • H372 Causes damage to organs through prolonged or repeated exposure.

Key precautionary statements

  • P203 Obtain, read and follow all safety instructions before use.
  • P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P260 Do not breathe gas.
  • P271 Use only outdoors or in a well-ventilated area.
  • P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
  • P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
  • P381 In case of leakage, eliminate all ignition sources.
  • P410+P403 Protect from sunlight. Store in a well-ventilated place.

Exposure limits

OSHA PEL
50 ppm (55 mg/m³) TWA
NIOSH REL
35 ppm TWA; 200 ppm Ceiling
ACGIH TLV
25 ppm TWA
NIOSH IDLH
1200 ppm

The federal OSHA PEL is 50 ppm TWA with no ceiling. NIOSH recommends 35 ppm TWA with a 200 ppm ceiling, and the ACGIH TLV is 25 ppm TWA. Cal/OSHA is stricter than federal OSHA at 25 ppm TWA and a 200 ppm ceiling. ACGIH also sets a biological exposure index based on carboxyhemoglobin in blood. Carbon monoxide has no odor or color, so continuous gas detection is the only reliable warning. State OSHA plans may set different limits.

Physical properties

  • Appearance: Colorless gas, shipped as a compressed or liquefied gas
  • Odor: Odorless
  • Molecular weight: 28.0
  • Boiling point: -313°F (-192°C)
  • Freezing point: -337°F (-205°C)
  • Flash point: Not applicable (flammable gas)
  • Autoignition temperature: 1125°F (607°C)
  • Explosive limits: LEL 12.5%, UEL 74%
  • Vapor pressure: Greater than 35 atm
  • Relative gas density: 0.97 (about the same as air)
  • Water solubility: 2%

Health effects

Inhalation

Carbon monoxide binds to hemoglobin and blocks oxygen delivery to the body. Early signs are headache, nausea, dizziness, weakness and rapid breathing, followed by confusion, chest pain, fainting and death at high levels. You cannot see or smell it.

Skin

The gas does not harm the skin. Contact with the liquefied gas causes frostbite.

Eyes

The gas does not irritate the eyes. Contact with the liquefied gas causes frostbite.

Ingestion

Not a relevant route for a gas.

Target organs

Cardiovascular system, lungs, blood, central nervous system

Long-term effects

Classified as a reproductive toxicant that may damage the unborn child, and as causing organ damage through prolonged or repeated exposure.

Personal protective equipment

Gloves

Chemical-resistant gloves selected using the manufacturer's permeation data. Use insulated gloves where contact with liquefied gas or cold equipment is possible.

Eyes and face

Safety glasses with side shields when handling cylinders. Add a face shield where liquefied gas could splash.

Respiratory

NIOSH lists no chemical cartridge respirators for carbon monoxide. It recommends supplied-air respirators up to 875 ppm; a full-facepiece gas mask with chin-style canister, self-contained breathing apparatus or full-facepiece supplied-air respirator up to 1200 ppm; and a pressure-demand self-contained breathing apparatus for emergencies or unknown concentrations.

Clothing

Flame-resistant, anti-static clothing where flammable concentrations could occur. Remove clothing promptly if it becomes wet with the liquefied gas.

Storage and handling

Store cylinders upright and secured, with valve caps in place, in a cool, dry, well-ventilated, separate area away from sunlight, ignition sources and oxidizers. Keep cylinder temperature below 125°F (52°C).

Use only in well-ventilated areas with continuous carbon monoxide monitoring. Use spark-proof tools and explosion-proof equipment, and purge lines with inert gas before maintenance.

Keep away from

  • Strong oxidizers
  • Bromine trifluoride
  • Chlorine trifluoride
  • Lithium

Spill response

  • Evacuate the area and call emergency responders.
  • Do not enter without a self-contained breathing apparatus and a gas detector.
  • Eliminate all ignition sources and use spark-proof tools and explosion-proof equipment.
  • Stop the leak if it can be done safely, and ventilate the area.
  • Follow ERG Guide 119.

First aid

If inhaled

Move the person to fresh air right away. Trained personnel should give oxygen, or artificial respiration if breathing has stopped. Get medical attention immediately and tell the doctor about the carbon monoxide exposure.

On skin

For frostbite from liquefied gas, warm the area gently with lukewarm water, not hot water. Get medical attention.

In eyes

For contact with liquefied gas, flush with plenty of water for at least 10 minutes and get medical attention.

If swallowed

Not a likely route of exposure for a gas.

In an emergency, call 911 or your local emergency number. For poisoning advice in the US, call Poison Control at 1-800-222-1222.

Firefighting

Suitable extinguishing media

  • Do not put out a leaking gas fire unless the leak can be stopped safely
  • Water spray to cool containers
  • Media suited to the surrounding fire

Special hazards

Carbon monoxide is extremely flammable. Cylinders exposed to fire can burst. Approach only with positive-pressure self-contained breathing apparatus, because the gas is toxic even when not burning.

Regulations

  • OSHA Hazard Communication (29 CFR 1910.1200): Hazardous chemical. Labels and safety data sheets are required.
  • OSHA Air Contaminants (29 CFR 1910.1000, Table Z-1): PEL 50 ppm (55 mg/m³) TWA.
  • EPA: Not listed as a CERCLA hazardous substance (40 CFR 302.4), an EPCRA extremely hazardous substance (40 CFR 355), or a Clean Air Act 112(r) regulated substance (40 CFR 68.130).
  • DOT (49 CFR 172.101): UN1016, Carbon monoxide, compressed, Division 2.3 with subsidiary hazard 2.1; poison inhalation hazard.

Sources

This library is a general reference compiled from public sources such as the NIOSH Pocket Guide, OSHA and PubChem. It does not replace the manufacturer's Safety Data Sheet for the product you use, which may differ by grade, concentration or supplier. Always check the SDS and current regulations before handling a chemical.

Last reviewedOctober 2026