Hexavalent chromium exposure is contact with chromium(VI) compounds from stainless steel welding, chrome plating and pigments, which can cause lung cancer and skin damage and is regulated by OSHA 1910.1026.

Hexavalent chromium exposure is breathing in, swallowing or touching compounds that contain chromium in its +6 oxidation state, written as Cr(VI). These compounds are produced in industrial processes, and some form when chromium-containing metals are heated.
Hexavalent chromium is a known human carcinogen. Breathing it over time raises the risk of lung cancer, and it can also damage the nose, throat and lungs, cause holes in the nasal septum, and cause skin ulcers and allergic dermatitis. It became widely known outside industry through the drinking water case portrayed in the film Erin Brockovich.
Hexavalent chromium is created during everyday work, not just in chemical plants. Any shop that welds or cuts stainless steel, sprays chromate primer or works with wet cement can create exposure. Because it is invisible in the fume and the health effects take years to appear, many employers do not realize they have a problem until air sampling or a customer audit reveals it.
It also affects people beyond the welder. Fume drifts to nearby workers, and dust on clothing can travel home. Good controls protect the whole workplace and help avoid costly citations under OSHA's specific Cr(VI) standards.
Breathing dust, fume and mist is the main concern for cancer. Skin contact with wet cement, plating solutions or contaminated surfaces causes burns, ulcers known as chrome holes and sensitization.
OSHA regulates Cr(VI) under 29 CFR 1910.1026 for general industry, 1915.1026 for shipyards and 1926.1126 for construction. Key requirements include:
A fabrication shop that mostly welded carbon steel won a contract for stainless steel tanks. Welders kept using the same flux-cored process and general shop fans. Personal air samples taken during the new job showed Cr(VI) levels above the 5 microgram limit.
The shop switched to a lower-fume process for the stainless work, added fume extraction guns, set up a regulated area around the welding bay, fitted welders with powered air-purifying respirators until new samples showed exposure under the action level, and enrolled them in medical surveillance.
OSHA's permissible exposure limit is 5 micrograms per cubic meter of air as an 8-hour average. The action level is 2.5 micrograms per cubic meter.
Yes. Stainless steel contains chromium, and the heat of welding converts some of it to Cr(VI) in the fume. The amount depends on the welding process, consumables and ventilation.
Long-term breathing raises the risk of lung cancer. It can also irritate and damage the nose and lungs, cause holes in the nasal septum, and cause skin ulcers and allergies.
No. Trivalent chromium, Cr(III), is much less toxic and is even a dietary nutrient. The +6 form is the one that causes cancer and the strict workplace limits.
It depends on measured exposure. A half-face respirator with P100 filters may be enough at lower levels, while powered air-purifying respirators or supplied air are used for higher levels. Respirators must be part of a full program with fit testing.
Personal air samples are collected on special filters in the worker's breathing zone and analyzed by an accredited lab using a Cr(VI)-specific method. Wipe samples can also check surface contamination.
Part of SafetyIQ's EHS glossary: plain-English definitions of workplace health and safety terms.
> Keep learning
> See it in action
Capture hazards, run inspections, track training and close out corrective actions in one platform built for high-risk, field-heavy work.
Book my free demo