An emergency action plan (EAP) is a written plan that sets out how employers and employees respond to fires and other workplace emergencies, including reporting, evacuation and accounting for everyone.

An emergency action plan (EAP) is a plan that describes what employers and employees must do during a fire or other workplace emergency. It covers how emergencies are reported, how people evacuate or shelter, who handles critical tasks, and how everyone is accounted for afterward.
A good EAP reduces confusion when every minute counts. Without one, workers may not know the alarm signal, the safest evacuation route or where to gather, and responders may waste time searching for people who are already safe. EAPs apply to offices, warehouses, plants, construction sites and any workplace where fires, chemical releases, severe weather, workplace violence or medical emergencies could occur.
Under 29 CFR 1910.38(a), an employer must have an EAP whenever another OSHA standard in Part 1910 requires one. Examples include the portable fire extinguisher standard (1910.157), when employees evacuate instead of fighting fires, and the process safety management standard (1910.119), which requires an EAP for the entire plant. Construction employers have parallel requirements at 29 CFR 1926.35. Even where not strictly required, OSHA recommends that all employers have one.
The plan must be in writing, kept in the workplace and available for employees to review. An employer with 10 or fewer employees may communicate the plan orally instead.
Start with a risk assessment of the emergencies your site could face, such as fire, gas leaks, chemical spills, severe weather, earthquakes, active threats or medical events. Some call for evacuation, while others, such as tornadoes or external chemical releases, call for shelter-in-place. The EAP should explain which action applies to which situation and how people will be told.
A food processing plant with 150 employees on two shifts uses ammonia refrigeration. Its EAP describes separate alarms for fire and ammonia release, assigns evacuation wardens for each area, names two operators who isolate the refrigeration system before leaving, and sets upwind and downwind assembly areas so workers can move away from a release depending on wind direction.
During a quarterly drill, wardens discover that forklift operators in the freezer cannot hear the ammonia alarm. The plant adds strobe lights in the freezer, updates the plan and reviews the change with affected employees. Supervisors also start using a shift roster at the assembly areas so the incident commander knows within minutes whether anyone is missing.
An EAP is required when an OSHA standard calls for one, and employers with 10 or fewer employees may communicate it orally. OSHA recommends that all employers have an EAP regardless.
An EAP covers how people respond once an emergency happens. A fire prevention plan, covered by 29 CFR 1910.39, focuses on preventing fires through hazard control, housekeeping and equipment maintenance.
OSHA requires review with employees when the plan is created, when an employee is first assigned, when their duties change and when the plan changes. Many employers also review it at least once a year and after every drill or real event.
Yes. The plan should explain how off-site and lone workers report emergencies, receive alerts and are accounted for, since they will not be at the main assembly area.
Part of SafetyIQ's EHS glossary: plain-English definitions of workplace health and safety terms.
> Keep learning
> See it in action
Capture hazards, run inspections, track training and close out corrective actions in one platform built for high-risk, field-heavy work.
Book my free demo